About a Typical Pneumatic Circuit
KVAL 994-X Operation/Service Manual
6-16
Typical Pneumatic Assembly
Pneumatic assembly setups vary in KVAL machines depending on where it is used and air
requirements.
This is a general overview of a pneumatic assembly
.
See the machine’s Air
Print for detailed information.
Air Input
Cylinder
Retract
Cylinder
Extend
Electrical Wiring Box:
Contains inputs from PLC
to Coils (Solenoids)
Manifold:
Base to accept air
input and output air.
Coil (Solenoid):
Receives
input(24V) from PLC to open a port
FIGURE 6- 33.
Typical Pneumatic Assembly
About the Coil (Solenoid)
The Solenoids are connected to the top of the manifold. Labels indicating their function and PLC
connections are attached to the solenoid body. Use this information to troubleshoot system if nec-
essary.
Solenoid type will vary with machine application.
Common controls include an operational LED and
Manual operation button
Manual Activate Button:
Push to toggle solenoid to the
‘ON’ state. activates if power is off.
Indicator:
a Lit LED indicates the solenoid is in
use.Red LED= the ‘A’ Port on a single valve. If double
valve, Red LED= the ‘A’ Port and Green LED = the ‘B’
port.
FIGURE 6- 34.
Solenoids in Manifold
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......