Location of Sensors on 994-X
6-23
KVAL 994-X Operation/Service Manual
Z Axis and Y Axis Front Section Sensors
Figure 6- 37 below shows the placement of the
Z-Axis
sensors and the
Y-Axis
sensors. The
Y-Axis
sensors sets the maximum limits in positive and negative vertical movement and also sets the
home position. The
Z-Axis
sensors sets the maximum limits in positive and negative depth move-
ment and also sets the home position.
Y-Axis Home Eye
Y-Axis Forward Crash Eye
Y-Axis Reverse Crash Eye
Z-Axis Home Eye
Z-Axis Forward Crash Eye
Z-Axis Reverse Crash Eye
FIGURE6- 37.
Figure 6- 37 Section View of 994-X Y and Axis Sensors