About the KVAL Calibration Routine
3-5
KVAL 994-X Operation/Service Manual
Calibration Slot Drilling Specifications
The calibration routine will route a slot with known dimensions as a reference. The placement of
the slot and the parameters of the cut can help in dialing in the calibration. Each tool in the Car-
riage Head will be part of the slot drilling process. For the steps to machine the slot,
Calibration Routine” on page 3-6.
The Calibration slot dimensions and position will vary with the diameter of the drills and the
door width.For information on making adjustments,
see “Check Specifications of the Front Sec-
TABLE 3- 2.
Cal Slot Dimensions
Assembly
Length
Width
Depth
Vertical Position
Position
Standard
Router
2.00 ''+ Diameter of Drill
Diameter of Router
0.050 ''
Center of Door Edge
Center of H- Block
C-Rotate
Router
2.00 ''+ Diameter of Drill
Diameter of Router
0.100 ''
Center of Door Edge
Center of H-Block
Drill
N/A
Diameter of Drill
0.250 ''
Center of Slot
Center of slot
Drill
Standard Router
Counter Rotate Router
H-Block Width 5-1/2””
Using the table above for ref-
erence dimensions, measure:
a.The Center of the Drill
hole
b.The centering of the
Standard Router Cut
c.The centering of the
Counter Rotate Router
Cut.
d.The Depths of all cuts
a
a
b
b
c
c
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......