About the Hopper
KVAL 994-X Operation Manual
4-20
About the Hopper
The Hopper sorts the screws for delivery to the screw gun. The Hopper is attached to the Frame
Interface which in-turn is attached to the Six/Eight Shooter. The Frame Interface allow the Six/
Eight shooter assembly to move across the machine.
Important:
Do not mix screw types in the Hopper. Different sizes, pitches can cause
uneven application of the hinge.
Important:
Do not adjust any of the Hopper air cylinders. They are adjusted at the
factory. Any adjustment may cause timing issues with the operation of
the Six Shooter. If you think problems are being caused by the cylinders,
please contact the
KVAL Service Department
for direction.
FIGURE 4-29.
Hopper and Frame Interface
Important:
Do not put Magnetized Screws in Hopper. Magne
-
tized screws can cause sluggish response to screws
getting stuck. Hopper plates could get magnetized
and will have to be demagnetized with a degausser.
Hopper
Quick Change Dump
Gate (Opt. Z)
Quick Change
Dump Cylinder
and Funnel
(Opt. Z)
Quick Change
Dump Con
-
tainer (Opt. Z)
Frame Interface
Hopper Cylinder
Screw Pick
Off Slide
Assembly
Screw Pick Off
Cylinder
Screw Delivery
Tubes Air Injected
Six Shooter
Six Shooter Pivot
Cylinder
Track Wheels
Plate Assembly
Cylinder
Gate Assembly
Screw
Tracking
Plate
Assembly
Quick Change Dump Gate
(8- shooter) (
Opt. Z1)
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Manual ...
Page 82: ...Calibration of the Back Section KVAL 994 X Operation Manual 3 22 ...
Page 124: ...KVAL 994 X Operation Manual 4 42 ...
Page 128: ...Index Kval 994 X ...
Page 129: ......