Calibration of the Back Section
KVAL 994-X Operation/Service Manual
3-18
FIGURE 3- 11.
Reference Door Lock
Adjusting Lock Location
1.
Select the size door (
6'8''-7'0''-8'0'') or Base.
2.
Select Right Hand or Left Hand depending on
the door run through process.
3.
Under Base, select the
Combine with Base
but-
ton.
4.
Enter a positive number to move the lock cut to
the left. Enter a negative number to move the
lock cut to the right.
5.
Re-run the lock cut.
6.
Measure again and repeat steps 3 to 4 until the
center of the lock is at the desired cut location.
7.
Once the completed with calibration, select the
Combine with Base
button to store the data.
8.
Exit Main Calibration Screen.
Fast and Slow Lock Plate Timing
Adjust
Fast Lock Plate Timing
under normal operating (No Extend Time), the router time can be
adjusted to match the flow controls on the machine. Before adjusting these times, make sure the
flow controls are set properly.
Note:
Before adjusting the Slow Lock Plate Timing, make sure the Fast Plate Routine
is set properly adjusted.
If the settings are in
Extend Time,
adjust the
Slow Lock Plate Timing.
FIGURE 3- 12.
Fast and Slow Lock Plate Timing Menu
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......