Lubrication Requirements
KVAL 994-X Operation/Service Manual
5-20
Adjusting the Air Line Lubricator
Using the knob on the top of the lubricator, adjust until one drop per every other cycle is used (as
observed through sight glass.)
(Sight Glass). When the oiler has run dry,
open the knob all the way until flow begins.
Once you have a steady flow, tighten knob
back down until you have one drop per
every other cycle.
Drop will form at end of cane shaped tube
visible inside glass.
Top of Lubricator
Priming the Air Line Lubricator
New and used machinery run out of oil from time to time. It is a good practice to check your
machine lubricator to insure that it is putting the proper dose of oil in the air lines. Usually 1 drop
of oil every other cycle is a good rule of thumb. The approved list of oil for lubricators is as fol-
lows:
• KVAL P/N SYSLUBG
• Chevron AW Hydraulic Oil 32
• G-C lubricants light AW R&O
• Mobile DTE 24
• Shell Tellus32
• Gulf Harmony 32
To prime the lubricator, find an air line on the carriage section of the machine that is energized,
and disconnect it, allowing the air stream to bleed air pressure away from any persons. Direct the
air stream at the machine so you can see when there is an oily film blowing out of the air hose.
Repeat this same procedure for the back section and other trouble areas.
It is recommended to check the lines every week to two weeks.
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......