a
b
Enter a negative number to move to the carriage left
Enter a positive number to move the carriage right
a
b
Check Specifications of the Front Section
KVAL 994-X Operation/Service Manual
3-10
FIGURE 3- 6.
Samples of X Axis Adjustments
Adjusting the Y Axis
1.
Run the Calibration Routine. See “Run the Calibration Routine” on page 3-6. Use
the H Block as a reference to determine the vertical center of the calibration slot.
Figure 3- 7 on page 3-11, shows an example of high and low
“off centralizations
.
2.
Measure the amount of material left between the
Actual
Door Width and the slot on
both sides of the slot (a and b).
3.
Calculate the difference between “a “and “b” and then divide by two. Refer to the
example located below.
4.
Next, what way does the slot need to move? To move up, enter a positive number.
To move down enter a negative number
5.
Locate the appropriate Menu in the Setup interface
screens.
6.
If there is a number in the box under Y-Axis, select the
Combine with Base
button to
set a reference.
7.
Once this number is added to the base, double select the box that has 0.000. A calcu-
lator will be displayed. Enter the offset in this box.
8.
Select the check mark to confirm this number and exit to go back to the Setup
screen.
9.
Exit out of the Setup screen and rerun the Calibration test.
10.
Re-measure the parameters of slot.
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......