About the KVAL Calibration Routine
KVAL 994-X Operation Manual
3-4
About the KVAL Calibration Routine
The calibration routine creates a reference cut to check settings against a “known good” source.
The routine is used to verify the front section. It routes a horizontal slot and drills a center hole at
precise specifications. Using these specifications as a reference, you can inspect the pattern and
the specifications of the slot for inaccuracies. The front end assemblies that use the calibration
routine are as follows:
1.
Hinge Carriage
2.
Router (Standard)
3.
Option CR: Counter Rotate Router to eliminate chipouts.
4.
Option CH: Chisels to square the cut
5.
Pre-Drill
FIGURE 3-2.
Location of Assemblies
Pre-Drill:
Drills pilot holes for
insertion of screws on
the jamb and the door
Router:
Routs the
hinge pocket on the
jamb and the door
Counter Rotate
Router:
Router
minimizes chip outs
on door and Jamb
Pre Drill:
Router:
Standard
Option CR
Standard
Option CH
Counter Rotate Router:
Router:
Standard
Chisels:
Two chisels per assembly. Square
off Jamb and Door hinge cuts.
Summary of Contents for 994-X