Check Specifications of the Front Section
KVAL 994-X Operation Manual
3-10
FIGURE 3-6.
Samples of X Axis Adjustments
Adjusting the Y Axis
1.
Run the Calibration Routine. See “Run the Calibration Routine” on page 3-6. Use
the H Block as a reference to determine the vertical center of the calibration slot.
Figure 3-7 on page 3-11, shows an example of high and low
“off centralizations
.
2.
Measure the amount of material left between the
Actual
Door Width and the slot on
both sides of the slot (a and b).
3.
Calculate the difference between “a “and “b” and then divide by two. Refer to the
example located below.
4.
Next, what way does the slot need to move? To move up, enter a positive number.
To move down enter a negative number
6.
If there is a number in the box under Y-Axis, select the
Combine with Base
button to
set a reference.
7.
Once this number is added to the base, double select the box that has 0.000. A calcu
-
lator will be displayed. Enter the offset in this box.
8.
Select the check mark to confirm this number and exit to go back to the Setup
screen.
9.
Exit out of the Setup screen and rerun the Calibration test.
10.
Re-measure the parameters of slot.
a
b
Enter a negative number to move to the carriage left
Enter a positive number to move the carriage right
a
b
5.
Locate the appropriate Menu in the Setup interface
screens.