About Calibration Sequence
KVAL Operation Manual
4-10
3.
Add the door to the Queue
4.
At the
Main Screen
, ensure the
Set-Up Mode
is
enabled (no cutting).
5.
At the
Main Screen
, ensure
Auto Feed
is enabled
6.
Feed in the reference door.
7.
Select the
Log Tab
and check the latest
Width and Lengt
h feedback located under the
Messages Column.
8.
Re-feed the door at least 3 times. (Each time capturing the measurements from the
Log Viewer).
9.
Reverse the door and re-feed it at least 3 times. (Each time capturing the measure-
ments from the Log Viewer).
10.
To get the average, add -up all data collected from the
Log Viewer
and divide by the
number of times the door was fed in.
11.
Compare the actual measured data with the calculated data.
12.
If the
width
measurement feedback is less that the actual measurement,
input a neg-
ative value
.
13.
If the
length
measurement feedback is
less
that the actual measurement,
input
a
positive
value
.
Summary of Contents for DL-NCD
Page 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Page 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Page 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Page 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Page 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Page 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Page 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Page 142: ......
Page 143: ......