Definitions
KVAL Operation Manual
2-20
Validation
All feature groups are analyzed by a validation routine before the software
permits the operator to download the programmed cut to the machines for
processing. The validation routine queries the capabilities of each machine
and current tools loaded to determine if the programmed cuts can be per-
formed by the line. If at least one machine in the line is capable of perform-
ing each cut / feature in the group, the group will be considered valid and
the Add to Queue button will be enabled. If any feature or cut fails valida-
tion, however, a Orange or Red box will be highlighted over the faulty cut /
feature for review and the Add to Queue button will be disabled. Red only
appears if the expression cannot be interpreted to a real number for valida-
tion, while orange appears if the line cannot perform the cut.
Validation
Report
Validation Report identifies particular faults that would cause a feature to
fail validation. Each feature has its own validation tests and will fail if the
tests for a valid feature are not satisfied. Clicking on a specific test will pro-
vide an explanation of the test being performed so that the user can correct
the mistake.
Validation will only work if the information that is fed to the machine line is
accurate. Inaccurate information that is downloaded from Tool Configura-
tions, Calibrations, or Libraries (e.g. material types) will produce unex-
pected or potentially harmful results to the machine and/or operator.
Some cuts in fringe cases may pass validation that result in non-conform-
ing cuts (cut does not match visual representation).
Term
Definition
Summary of Contents for DL-NCD
Page 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Page 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Page 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Page 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Page 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Page 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Page 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Page 142: ......
Page 143: ......