About Calibration
KVAL Operation Manual
4-2
Calibration is all about the confidence in the end results of your manufacturing process. Calibra-
tion assures you that your cut parameters are accurate and within the specified limits.
If slight discrepancies in the machining of a door are observed, the built in KVAL calibration can
adjust the tooling to fix the issue.
In troubleshooting, calibration can be an essential step in solving the issue.
About the Calibration Menus and the Calibration Reference Cut
This chapter describes the
Calibration Menus
.
In the
Calibration Menus
, offsets are entered to calibrate assemblies in the machine.
the Calibration Tabs” on page 4-3.
Before you Calibrate
Before you start calibration, check for the following common issues.
1.
Is the loaded setup correct for the current cut?
2.
Check tools for wear.
3.
Is the correct Calibration loaded?
4.
Are the stops set up correctly?
5.
When did the problem first start? during a run, at start up.
6.
When was the last calibration?
7.
Is the Door True?
8.
Check for sawdust build-up, which may affect depth.
Note:
KVAL recommends that a test door is run first and checked for specifications
before a full run is started.
Summary of Contents for DL-NCD
Page 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Page 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Page 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Page 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Page 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Page 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Page 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Page 142: ......
Page 143: ......