Description of the Light Tower
3-29
KVAL Operation Manual
Description of the Light Tower
The Light Tower indicates the working status of the system. Highly visible indicator lights are
mounted on top of the Electrical Boxes. A series of colors and flashing codes helps determine the
machine error.
The sequence the lights activate as follows:
Light
Light
Position
Category
Description
3
Top
Machine Status
Off
: Machine Non-operational
White
: Initializing
• 1 Flash: Waiting for all systems to initial-
ize
Red:
Machine Error
• Solid: General error
• 1 Flash: EtherCat device not ready to run
• 2 Flashes: VFD, servo, or motor fault.
• 3 Flashes: 24vdc power error. (over-cur-
rent, fault, etc)
Yellow:
External Error
• Solid: General error.
• 1 Flash: 3-phase voltage error.
• 2 Flashes: Low air.
Green:
Operational
2
Middle
Safety
Off:
Safety project not running
Red:
Safety PLC error
Blue:
Waiting for safety-reset
• Solid: General error.
• Flashing: Not ready to re-start (e-stop
switch active).
Green:
Operational
1
Bottom
Control Power
Off:
No Control Power
On:
24 VDC control power activated and
working.
All lights lit green indicates the machine is operational
Summary of Contents for Edge-SS
Page 4: ...KVAL Edge SS System Operation Manual ...
Page 6: ...KVAL Edge SS System Operation Manual ...
Page 12: ...KVAL Edge SS Manual Table of Contents ...
Page 49: ...About Revisions 2 16 KVAL Manual ...
Page 84: ...Common Terms 2 51 KVAL Manual FIGURE 2 11 Example of a Validation Report ...
Page 147: ...About the Nodes 5 21 KVAL Operation Manual ...
Page 149: ...Index Kval Edge SS clean up 12 inspect 12 ...
Page 150: ......
Page 151: ......