Step 2: Calibrate the Length and Thickness Feelers
KVAL Operation Manual
4-13
6.
Feed in the reference door.
7.
Select the
Log Tab
and check the latest
Thickness and Lengt
h feedback located under
the
Messages Column.
8.
Re-feed the door at least 3 times. (Each time capturing the measurements from the
Log Viewer).
9.
Reverse the door and re-feed it at least 3 times. (Each time capturing the measure-
ments from the Log Viewer).
10.
To get the average, add -up all data collected from the
Log Viewer
and divide by the
number of times the door was fed in.
11.
Compare the actual measured data with the calculated data.
12.
If the
thickness
measurement feedback is
less
that the actual measurement,
input a
positive value
.
13.
If the
length
measurement feedback is
less
that the actual measurement,
input
a
neg-
ative
value
.
3.
Add the door to the Queue
4.
At the
Main Screen
, ensure the
Set-Up Mode
is
enabled (no cutting).
5.
At the
Main Screen
, ensure
Auto Feed
is enabled
Summary of Contents for EFX
Page 10: ...KVAL EFX Manual Table of Contents ...
Page 32: ...Safety Sign Off Sheet KVAL Operation Manual 1 22 ...
Page 66: ...About the LiteCutout Feature Detail DL NCD Only KVAL Operation Manual 2 34 ...
Page 95: ...Appendix About Backing up the Data 3 29 KVAL Operation Manual ...
Page 112: ...Step 4 Calibrate the Face Axes KVAL Operation Manual 4 17 X Y Z X Y Z Y ...
Page 121: ...Routers How to Isolate and Calibrate a Specific Router KVAL Operation Manual 4 26 ...
Page 136: ......
Page 138: ...Index 1 2 Kval EFX ...
Page 139: ......