Step 7: Calibrate the Edge Tools
KVAL Operation Manual
4-23
Edge Tools Calibration Reference Cut
Predrill
Routers
Chisels
+
Z
-
Z
+
X
+
Y
-
X
-
Y
FIGURE 4-7.
Offset direction
+
Z
Check location of the predrill cut. Measure and
compare against the
Door Job
specifications. If
needed, input the offset polarity as seen in the
figure above.
Check location and shape of the Router cuts.
Look for stair step cut. (Counter Rotate and
Standard Router not aligned). Check the
Tool
Path Review
page to isolate routers. Use
Tool
Config
to turn routers on or off to isolate.If
needed, input the offset polarity as seen in the
figure above.
See “Routers: How to Isolate and Calibrate a
Specific Router” on page 4-24
Check location and shape of each corner cut.
If needed, input the offset polarity as seen in
the figure above.