3,000 Cycle Maintenance Steps
3-7
KVAL Service Manual
3,000 Cycle Maintenance Steps
Follow Lockout Tagout procedures,
Inspect Feed Belts (If Applicable)
Inspect all Photo Eyes
Inspect Limit Switches
Inspect feed belts for proper tension
or damage.
Check belts for cuts and nicks.
Belts can stretch over time. Check for
looseness. A rule of thumb is to pull
belt, if belt moves too freely, then
replace belt.
Belts can become slick from use, lesson-
ing traction on door. Check belts for
slickness or door slippage.
Inspect all photo eyes secure and tight.
Check Connection to Photo Eye
Check Nut that
attaches Photo Eye
to Machine
Inspect all limit switch arms for tightness or breaks.
Inspect the switch for cracks in the body and check that the
switch arm actuates (clicking sound) when moved to the
extreme.
Note:
Depending on the model of limit switch,
the amount of "pre-travel" (amount of
movement from the arms resting position)
is either 5 or 20 degrees before the limit
switch actuates.