About a Typical Pneumatic Circuit
4-13
KVAL Service Manual
Typical Pneumatic Assembly
Pneumatic assembly setups vary in KVAL machines depending on where it is used and air
requirements.
This is a general overview of a pneumatic assembly
.
See the machine’s Air
Print for detailed information.
FIGURE 4- 29.
Typical Pneumatic Assembly
About the Coil (Solenoid)
The Solenoids are connected to the top of the manifold. Labels indicating their function and PLC
connections are attached to the solenoid body. Use this information to troubleshoot system if nec-
essary.
FIGURE 4- 30.
Solenoids in Manifold
Air Input
Cylinder
Retract
Cylinder
Extend
Electrical Wiring Box: Con-
tains inputs from PLC to
Coils (Solenoids)
Manifold: Base to accept air input
and output air.
Coil (Solenoid): Receives input(24V)
from PLC to open a port
Solenoid type will vary with machine application.
Common controls include an operational LED and
Manual operation button
Manual Activate Button: Push to toggle solenoid to the
‘ON’ state. activates if power is off.
Indicator: a Lit LED indicates the solenoid is in use.Red
LED= the ‘A’ Port on a single valve. If double valve,
Red LED= the ‘A’ Port and Green LED = the ‘B’ port.
Summary of Contents for EFX
Page 4: ...KVAL EFX System Service Manual ...
Page 6: ...KVAL EFX System Service Manual ...
Page 11: ...Notes ...
Page 31: ...Safety Sign Off Sheet KVAL Service Manual 1 20 ...
Page 35: ...About Backing up the Data KVAL Service Manual 2 4 ...
Page 75: ...Collet Torque Values KVAL Service Manual 3 40 ...
Page 76: ...Notes ...
Page 103: ......
Page 106: ......
Page 107: ......