Step 1: Calibrate the Carriage Stop
KVAL Operation Manual
4-11
Step 1: Calibrate the Carriage Stop
For this calibration, make sure the distance from the cutting space to the first carriage stop is at 20
inches.
Important:
The
Carriage Stop
is the starting reference for the calibrations on the
machine. Always verify the carriage stop setting before continuing to cal-
ibrate.
Procedure
After homing the machine, measure the distance between edge of the cut area that is closest to the
Operator’s Station
to the farthest
Carriage Stop
. The distance should equal 20 inches.
If not in specification, adjust the location. Repeat until specification is reached. For polarity of
value to enter,
see “Door Edge Axis Directions” on page 4-5.
FIGURE 4-6.
Stop Calibration
20.0 ''