Step 3: Calibrate the Depth Feeler (Option)
KVAL Operation Manual
4-14
Step 3: Calibrate the Depth Feeler (Option)
For instructions about entering calibration data,
see “How to Enter Calibration Data” on page 4-7.
At the
Calibration Screen
, select
Door Stops and Feelers
to display the calibration menu.
Note:
For this calibration step, a known good door is sent through the machine multi-
ple times.
Before Calibrating
Before calibrating the Lock Probe depth (
Z-Axis
) verify the
X-Axis
and
Y-Axis
.
This is a visual test.
Run a Door Job. Check the Depth
Probe Pad position as it touches the
door edge. Pad on probe should
cover at least 50% of the door edge.
+
X
+
Y
-
X
-
Y
Probe Pad
Probe Pad
Door Edge
Pad covers door edge at
least 50% coverage