Kvaser Memorator Professional User’s Guide
20 (37)
If everything is OK, the green PWR lamp should either blink
quickly, or be illuminated 90% and dark 10% of the time. If CAN
traffic is detected, the CAN1 and CAN2 lamps should be
illuminated.
4.4
Kvaser Memorator Tools
To log CAN traffic with the Kvaser Memorator Professional, you need to create and
download a configuration to the device. The Kvaser Memorator Professional needs
to be connected by USB and have a disk inserted to be configured. Start the PC
application Kvaser Memorator Tools and press the
Connect
button in the toolbar. If
the LEDs on Kvaser Memorator Professional are flashing in a “running light”
pattern, the device is ready to communicate with Kvaser Memorator Tools.
For further information about Kvaser Memorator Tools please refer to its online
help.
4.5
Disk management
•
Handle the disks with care. They are robust, but better safe than sorry.
•
Avoid removing the disk when the device is powered up from an external
power source. You should first remove the external power and then remove
the disk. If the device is connected via USB, you should make sure the
Kvaser Memorator Tools isn’t writing to the disk before you remove it.
•
You
may
remove and reconnect the disk, the external power and the USB in
any order you like without damaging the
hardware
. But if you follow the
advice above, you will not damage
your logged data
.
•
If you need to remove the disk when the device is being used as a logger and
you can’t disconnect the external power, try to connect the USB cable to a
running PC first. When the Kvaser Memorator Professional discovers the
active USB connection, the device will stop logging and close the log file in
an orderly fashion.
Kvaser AB, Mölndal, Sweden — www.kvaser.com