Kvaser Memorator Professional User’s Guide
29 (37)
No error messages should appear.
If you see error messages,
try to disconnect and reconnect the device, and then perform the
operation again.
To verify that the firmware is updated,
•
Double-click on “Kvaser Hardware” in the Control Panel. Select “Kvaser
Memorator Professional” in the tree view to the left, and click on either
channel. The firmware revision information appears in the right half of the
window.
5.8
Required driver version
You need at least driver (CANlib) version 3.9 to use your Kvaser Memorator
Professional.
5.9
Write protection switch
Kvaser Memorator Professional will
disregard
the setting of the write protection
switch on SD and SDHC memories. This is by design. The intention is to minimize
the risk of a logging failure when the write protection switch is set by accident.
The setting of the write protection switch on SD and SDHC
memories is disregarded. The Kvaser Memorator
Professional will write to the disk even if the write protection
switch is set.
5.10
CAN bus termination
Every CAN bus must be terminated with a 120
Ω
resistor at each end of the bus.
The Kvaser Memorator Professional does not contain any CAN bus terminators,
because their inclusion could cause severe disturbance in a system which is
already correctly terminated.
For laboratory or testing use, the exact value of the termination resistors is not
always critical. Sometimes a single terminator is sufficient. For production, proper
termination is essential. If you see error frames on the bus, you should check the
termination.
Kvaser AB, Mölndal, Sweden — www.kvaser.com