Kvaser Memorator 2xHS v2 User’s Guide
19 (26)
Figure 7: Example of how to connect a button to the External trigger input.
The trigger input is debounced by the firmware so that a pulse of shorter length
than approximately 30 ms will not be detected.
Internally, the External trigger input has a pull-up to +5 V, see Figure 8 on Page 19
Figure 8: The External trigger input inside the Kvaser Memorator 2xHS v2.
4.6
External trigger output
The Kvaser Memorator 2xHS v2 can be set up to send an external pulse through
the External trigger output pin. See Section 4.3, CAN connectors, on Page 17 for
pin numbering.