Kvaser Memorator Light HS v2 User’s Guide
13 (19)
Figure 4: The D-SUB 9 connector pin numbers
D-SUB pin number
Function
1
Not connected
2
CAN_L
3
GND
4
Not connected
5
Shield
6
Not connected
7
CAN_H
8
Not connected
9
Power supply to the device
Table 10: Configuration of the 9-pin D-SUB
4.3
CAN bus termination
Every CAN bus must be terminated with a 120 Ohm resistor at each end of the
bus. The Kvaser Memorator Light HS v2 does not contain any CAN bus
termination, because their inclusion could cause severe disturbance in a system
which is already correctly terminated.
For laboratory or testing use, the exact value of the termination resistors is not
always critical. Sometimes a single terminator is sufficient. For production, proper
termination is essential. If you see error frames on the bus, you should check the
termination.
To save yourself a lot of trouble, always terminate the CAN
bus properly.
4.4
Kvaser Memorator Config Tool
The Kvaser Memorator Config Tool is required for two tasks:
1. To extract logged data
2. To clear or reinitialize the built-in disk
For further information about the Kvaser Memorator Tools, please refer to the
program’s online help.
Kvaser AB, Mölndal, Sweden — www.kvaser.com