4.2
Wiring the Gyro for Digital Synchronous Operation
Use the wiring diagram below as a guide to connect the gyro to your application.
Figure 8: Wiring Diagram
(Synchronous Operation)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
5 VDC
RETURN
DC SUPPLY
+5 VDC
POWER COMMON
CASE GROUND
Tdata
Tsync
Tclk
BIT
CUSTOMER
INTERFACE
SIGNAL COMMON
Msync
(Optional)
4.2.1 Wiring Guidelines
Be sure to follow the guidelines below to ensure optimum performance.
•
The chassis ground, pin 3, as well as the housing, should be coupled to the system
ground with minimum impedance. The surface on which the gyro is mounted
should not inject AC noise onto the gyro housing as it will radiate into the gyro
electronics.
•
Twisted-shielded-pair should be used to connect the gyro output to the user’s
interface. Cables should be as short as possible, not to exceed 12" (30 cm) in
length.