Chapter 5: Troubleshooting
Status signaling
115
0800D
Antenna
Overvoltage
protection is
activated
Overvoltage is detected in
the antenna. The terminal
will be shut down in 10
minutes.
Do not use the terminal.
Contact your dealer/
distributor.
08010
Undervoltage
has been
detected
The input voltage has
dropped below an
acceptable level. The
terminal will be shut
down in 10 seconds if the
situation persists.
Ensure a stable power
supply to the terminal.
0801B
Lost connection
to the GPS
receiver
Communication with the
GPS receiver in the
antenna is lost.
Restart the terminal.
Contact your dealer/
distributor if the warning
persists.
0801D
Uploading
firmware to
antenna
New firmware is being
uploaded to the antenna.
The Event will be cleared
when upload has finished.
Contact your dealer/
distributor if the Event is
not cleared within 5
minutes.
0802C
Firmware update
still fails
after several
retries
The terminal was unable
to upload new firmware to
the antenna.
Contact your dealer/
distributor.
0802D
Firmware update
failed
The terminal was unable
to upload new firmware to
the antenna.
Reboot the terminal. Then
update the software again.
Contact your dealer/
distributor if the problem
persists.
0802E
Firmware is
older than
current antenna
version
The firmware in the
antenna is newer than
expected by the terminal.
Update the terminal
software.
0802F
Antenna main
image could not
be loaded
Antenna failed to start up
normally.
Reboot the terminal.
Contact your dealer/
distributor if the problem
persists.
08030
Antenna could
not enter main
application
mode
Antenna failed to start up
normally.
Reboot the terminal.
Contact your dealer/
distributor if the problem
persists.
ID
Event Text
Explanation
Remedy
Summary of Contents for TracPhone FB150