Check all connectors on the Antenna Baseplate
and IRD. Remove connectors and examine for
signs of corrosion; clean as needed.
Semi-Annually
•
Remove the radome and examine the interior of
the Antenna Unit for signs of corrosion, loose
connections, or frayed or broken wires.
4.3
TracVision 6 Field
Replaceable Units
The TracVision 6 has been designed with durability and low
maintenance in mind. If you experience an operating problem or
otherwise require technical assistance, contact your local
authorized TracVision 6 dealer/installer or distributor first. If an
authorized dealer/installer or distributor is not located nearby,
contact KVH or KVH Europe directly at the telephone, facsimile,
or e-mail listings inside the front cover.
Replacement part numbers for field replaceable units (FRUs) that
can be serviced in the field are listed in Table 4-1. These parts
may be obtained from any KVH authorized dealer/installer or
may be ordered directly from KVH.
FRU
Part Number
Radome
02-1047-01
CPU
02-0992
RF Detector PCB
02-1017-02
Antenna Gyro Sensor
02-1035
Antenna Gyro Gasket
24-0139
Elevation Drive Belt
24-0105-83
Elevation Motor
02-1050
European LNB Assembly
02-0932
U.S.-style LNB Assembly
02-0870
Latin American LNB Assembly
02-0870-01
Data Cable
32-0619-100
Switchplate
02-1023
4-2
TracVision 6 Installation and Technical Manual
Table 4-1
TracVision 6 Field
Replaceable Units
TracVision 6 components receive
power from multiple sources. Do
not open any electrical assemblies
or attempt servicing until IRD power
and vessel input power are
disconnected.