40 | kvm-tec
3. EXTENDER MENU/SETTINGS
Local Unit Pinout (DCE):
Pin
Function
Direction
2
TxD
OUT
3
RxD
IN
4
DTR
IN
5
GND
—
8
CTS
OUT
The pin numbers refer to a 9-pin D-sub plug.
The baud rate can be set in the menu. There is a universal setting for baud rates up to 9600
which transmits all different RS232 configurations transparently. For higher baud rates the
following settings are available via the menu:
Baudrate
Parity Stopbits
4800
No
1
9600
Odd
2
19200
Even
38400
Mark
57600
Space
115200
230400
T
Remote Unit Pinout (DTE):
Pin
Function
Direction
2
RxD
IN
3
TxD
OUT
4
DTR
OUT
5
GND
—
8
CTS
IN
Summary of Contents for 6701i
Page 28: ...28 kvm tec 3 EXTENDER MENU SETTINGS Plug in the USB stick and wait for a moment ...
Page 29: ...kvm tec 29 3 EXTENDER MENU SETTINGS Wait until all 4 phases have been completed ...
Page 50: ...50 kvm tec 3 EXTENDER MENU SETTINGS Videosharing ...
Page 82: ...82 kvm tec 12 15 NOTES ...
Page 83: ...kvm tec 83 www kvm tec com ...