EN
Instruction Manual
Hydropneumatic tool for rivet nuts from M3 to M10
with stroke and pressure adjustment
FASTSETM10
www.kvt-fastening.ch
32
6.3 -
TOOL PREPARATION AND SCREW REPLACEMENT
P 2
Warning:
Tool setting and screw replacement must be carried out with the tool disconnected from
the air supply line.
Figure 6.2 – A
To replace screws you have to carry out the following operations:
Unscrew the toothed ring
1
from the tool. Insert joint
2
. Insert screw
3
. Insert screw adapter
4
. Screw the toothed
ring
1
considering that the screw (or tie rod) must oscillate, then try and find the most suitable joint (see indented
ring). Screw
5
and
6
.
Figure 6.2 – B
1
3
2
1
5
6
4
Press with two fingers the little pin,
sliding it inside the hole and
unscrew the ring simultaneously.
TO UNSCREW THE KIT HOLDER QUICK RING
Between the casing and
the nut, there must be a
distance of 1.5 mm for
motor screwing.