Searching for an error
error
reason
help
o
The pump does
not start by using
the button
o
The pumps is not
switched on
o
The cable is not
connected
o
The optoelectronic
sensor is not in the
0-position
o
Pump is damaged
o
Switch the main-switch
on
o
Connect the cable
o
Put the optoelectronic
sensor in the 0-position
o
Check the pump
o
The pump goes
on but it switched
off immediately
o
The high-pressure
hose is not
connected right
o
Coupling or male-
couple is damaged
o
Check all hydraulic
connections
o
Exchange the damaged
items
o
The way of the
piston is to short
during the
pressure-
structure
o
Error at the pump
o
Check the pump (see in
the operating manual of
the pump)
o
You can not
adjust enough the
height-adjustment
o
Air in the hydraulic
system of the
height-adjustment
o
Air the hydraulic-
system, refill oil
o
After the switch
on of the pump
the tool moves
with a delay
o
Air in the hydraulic-
cylinder
o
Air the hydraulic-system
7
Servicing, maintenance, storage and transportation
The contact rail machining centre SSBZ and the tools have nearly not to be checked.
Regularly the appliance and the tools have to be cleaned and the movable parts have to
be greased a bit.
The rests of the punching have to be removed from the basic device. During the changing
of the tools please take care that no dirt gets into the conduction. You should use cutting-
spray for the increase of the lifetime of the punching- and cutting tools.
Also you have to look that the latch-bolts of the punches are always locked in the piston
during the working-process.
After each use, the SSBZ and the tools should be stocked clean and dry.