Diajekt Control CFC10
25
Status: 06/18/2014
P17
Control I-ratio
Integral ratio of the chimney fan
control
0.000 ... 10
0.511
-
P18
Control D-ratio
Differential ratio of the chimney fan
control
0.000 ... 10
0.255
-
P19
Control sampling
time
Sampling time of the chimney
fan control
1 ... 1000
100
[ms]
P20
Differential
pressure switch
CF feedback
States if a feedback signal from
the chimney fan should be
monitored
Yes
No
no
-
P21
Scaling factor
Factor for the linear scaling of
the differential pressure sensor
-100 ... +100
10
]
P22
Scaling offset
Offset
-500 ... +500
0
[Pa]
1.8.2 Configuration Tool
“
DiajektConfig
“
“
DiajektConfig
” is a configuration tool for parameterizing the Diajekt Control CFC10 and is
used to:
• parameterize the control unit
• readout the error memory
• reset the error memory
• update the control unit‟s firmware.
Figure 16: Start window "
DiajektConfig
"