INSTRUCTION MANUAL
OPERATING PRESSURE ADJUSTMENT
The pressure switch is located on the top of the sprayer. Sprayer operation at 1.3 bar (Fig. 10a). Sprayer
operation at 3 bar (Fig. 10b).
STORAGE AND MAINTENANCE
After each use, rinse the sprayer system thoroughly with clean water. Dilute the remaining spraying liquid in the
tank with water (approx. 2 litres) and then rinse the sprayer system by activating pumping until the tank is empty.
It is best to repeat the washing process up to 3 times. Rinse the strainer too.
The filter (Fig. 11/item 1) located in the lance handle (Fig. 11/item 3) and the nozzle (Fig. 12/item 1) at the end
of the lance (Fig. 1/item 7) should be cleaned periodically or before any extended period without operation.
The same applies to the filter at the bottom of the main tank (Fig. 14/item 2). The filter can be accessed by
unscrewing the filling unit safety cap (Fig. 1/item 3). The filter is located at the bottom of the tank.
The sprayer should be stored
WITHOUT PRESSURE IN THE PRESSURE TANK
at +5°C to +35°C in shaded
and dry places, away from heaters and out of reach of children. The device may be transported holding it by the
straps (Fig. 1/item 2) or by the transport handle on top of the device (Fig. 1/item 6).
De-pressurising the pressure tank:
1. Point the tip of the lance at the previously sprayed surface.
2. Press the lever (Fig. 11/item 2) and start spraying.
3. Continue spraying until no spraying liquid or pressure is emitted from the lance tip.
2
3
1
1
Fig.12
Fig.11
Fig.10a
Fig.10b