background image

KWE P

/N 542 0

18 Ve

rsatronik 

COMO OT 

Q

ui

ck

 Sta

rt-Up 

V1.0

 01/

2009 Tec

hnic

al

 inform

at

io

subject

 to c

ha

nge

 without noti

ce 

KWE Technologies Group 
750 McMurray Road 
Waterloo, Ontario, Canada 
N2V 2G5 
Tel: (519) 747-5042 
Fax: (519) 747-4448 
www.kwe-tech.com 
info@kwe-tech.com 

IMPORTANT 

Read and save these instructions for 

future reference 

 

 

Operating mode selector switch

 

 

ECO key (interruption of heating time) 

  Party key (heating time extension) 

  

Modification of set room temperature 

Press the operating mode selector button as 

often as necessary to set the operating mode 

required. The selected operating mode is 

represented by a symbol in the display. It takes 

effect when the selected setting remains 

unchanged for 5 sec. 

 

The following operating modes are available for 
selection: 

i

  

Standby / OFF 

(heating OFF, only frost protection function 

active) 

 

F

Automatic mode  

(heating according to time program 1) 

 

F

Automatic mode  

(heating according to time program 2) 

 

F

 

 

Summer mode  

(heating OFF, only hot water preparation 

active) 

 

h

 

 

Day mode (Normal mode) 

 

(24 hour heating at comfort temperature 1)  

 

C

  

Night mode (Reduced mode) 

(24 h heating at economy temperature) 

D

F

1

A

B

C

E

F

I

G

H

D

J

J

A Current time 
B  Set room temperature (represented in 

degrees Celsius) 

C  Day (1=Monday, 2=Tuesday, ..., =Sunday) 

(as shown, 3 = Wednesday) 

D  Bus symbol (if this symbol does not appear, 

check the data cable to the boiler) 

E  Indicates the active heating program (as 

shown 6:00 to 9:00 and 14:00 to 23:00) 

F Status indicator: 

H

 

burner ON; 

Z

 

D

 

heating 

operation; 

Z

 

F

 

hot water preparation 

G  Mode selector switch (as shown 

F

 

1 => 

Heating according to time program 1) 

Mode indicator and current status (here: 

B

 

II 

=> Heating with set room temperature 2)

 

Display of the current room temperature

 

Versatronik Como OT Quick Start-up 

Display Overview 

Mode Selection 

Summary of Contents for Versatronik COMO OT

Page 1: ...use of flat blade screwdriver Tilt user interface from sub base by hinging from the top Mount sub base at desired location by utilizing field supplied fasteners through mounting holes Make wiring connections 1 Sub base OT communication terminals 1 and 2 2 Sub base Outdoor Temperature Sensor to terminals 5 and 6 3 Connect OT communication wires to Viessmann Vitodens X3 3 and X3 4 Tilt front of cont...

Page 2: ...om Des2 T Room Des3 T Reduced Max Modulati Max T HS T Absence Return C F HotWProg Display T Outside T Room T DHW T HS Burner Start Burner Time Modulation Return Water Press Time Date Adjust HTG Prog2 Adjust HTG Prog1 Adjust Time Day Time Selection Day Selection T Room Adjust Out Temp Del Heatslope 2 Rooms Infl2 English Display 20 23 22 21 24 268 04 Return Ä Programming key a Select a value level b...

Page 3: ...0C 68F Ð T ROOM DES2 20C 68F Ð T ROOM DES3 20C 68F Ð T REDUCED 20C 68F Ð T ABSENCE 20C 68F Ð MAX T HS 85o C 185o F Ð MAX MODULATI 80 Ð o C o F Select Ð RETURN EXPERT Settings Settings Ð HEATSLOPE 1 0 Ð ADAPTION 1 Ð ROOM INFL1 Ð l CONTROL OFF Ð HEAT UP OPTI 0 Ð MAX OPT TIME 0 3 2 00h Ð N OPT TIME Display only Ð T ROOM ADJUST 0 Ð OUT TEMP DEL 50C 122F Ð HEATSLOPE 2 0 Ð ROOMS INFL 2 Ð DISPLAY 0 1 0 Ð...

Page 4: ...OFF only frost protection function active F1 Automatic mode heating according to time program 1 F2 Automatic mode heating according to time program 2 F Summer mode heating OFF only hot water preparation active h Day mode Normal mode 24 hour heating at comfort temperature 1 C Night mode Reduced mode 24 h heating at economy temperature D F1 A B C E F I G H D J J A Current time B Set room temperature...

Reviews: