10
Chapter 2 - Technical Data
106 V3.2
LEVEL RANGE
Measuring Ranges
SAT 30 – 120 dBµV
TV 20 – 120 dBµV
FM 20 – 120 dBµV
RC 25 – 120 dBµV
DAB 20 – 120 dBµV
Resolution 0.1 dB
Measuring accuracy ± 1.5 dB (at 20°C) warm up time > 5 min.
± 2.0 dB (0°C – 40°C) warm up time > 5 min.
Measuring bandwidth
SAT DVB-S/S2 8 MHz, 4 MHz or 1 MHz depending on symbol rate
TV analog Video carrier 200 kHz
Audio carrier 200 kHz
DVB-C 4 MHz, 1 MHz, or 200 kHz depending on symbol
rate
FM 200 kHz
RC 1 MHz, 200 kHz or 90 kHz depending on bandwidth
symbol rate setting
EMI 200 kHz
DAB 1 MHz
Acoustic level trend
indicator
can be switched on/off
ANALYZER
Measuring bandwidth
SAT 8 MHz, 4 MHz, 1 MHz
(RBW(-3dB))
TV 4 MHz, 1 MHz, 200 kHz, 90 kHz
FM 200 kHz, 90 kHz
DAB 1 MHz, 200 kHz
RC 200 kHz, 90 kHz
Span (frequency segment)
SAT Total range, 600 MHz, 150 MHz, 75 MHz
TV Total range, 250 MHz, 100 MHz, 50 MHz, 25 MHz
FM Total range, 10 MHz
DAB Total range, 30 MHz
RC Total range, 20 MHz
MAX hold function
Switch directly between analyzer mode and receiver mode