background image

KOM300M  User’s  Manual  201110 

 

 

KOM300M 

Industrial Media Converter 

Hardware Installation Manual 

 
 
 
 

 

Kyland Technology Co., LTD. 

 

 

 

 

 

 

Publication Date: Oct. 2011 

Version: V1.0 

Customer Service Hotline: (+8610) 88796676 

FAX: (+8610) 88796678 

Website: 

http://www.kyland.cn

 

E-mail: support@kyland.biz 

No.: 1.12.02.2009-0 

 
 
 
 

Summary of Contents for KOM300M

Page 1: ...strial Media Converter Hardware Installation Manual Kyland Technology Co LTD Publication Date Oct 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn...

Page 2: ...e and as up to date as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users Copyright 2011 KYLAND Technology CO LTD All rights reserve...

Page 3: ...o not tie or wrap the cable which may cause a fire risk z Power connectors and other equipment connectors should be firmly interconnected and checked frequently z Do not repair the equipment by yourse...

Page 4: ...4 Mounting 6 4 1 Dimension Drawing 6 4 2 Mounting Steps 8 5 Cable Connection 10 5 1 10 100Base T X Ethernet port 11 5 2 100Base FX Ethernet Port 12 5 3 Power 13 5 4 Grounding 14 6 LED Indicators 15 7...

Page 5: ...ia converter that can be applied extensively in wind power distribution network automation subway PIS power SCADA wastewater treatment metallurgy intelligent transportation rail transit and many other...

Page 6: ...Base FX port LED 4 Run Run LED 5 1 100Base FX port 6 2 3 two 10 100Base T X RJ45 ports 7 RJ45 port Speed LED 8 RJ45 port Link ACT LED Figure 1 Front Panel 3 2 Top Panel 1 Terminal block for power inpu...

Page 7: ...3 DIN Rail Mounting Dimension Drawing z Dimension Drawing for Panel Mounting Unit mm Figure 4 Panel Mounting Dimension Drawing Note The switch housing is a part of the heat dissipation system which b...

Page 8: ...evice in the direction of arrow 2 to put the whole Din Rail into the seat verify the KOM300M is firmly mounted on the DIN Rail as shown in Figure 5 Figure 5 DIN Rail Mounting z Remove KOM300M from DIN...

Page 9: ...ected position according to the panel mounting dimension drawings use a cross screwdriver to screw 4 cross slot screws M3 10 into holes Don t tighten the screws completely leave about 5mm of space bet...

Page 10: ...ecific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the device up to let screws into 4 holes with the diameter of 6 5mm 6 5 as seen in arrow 1 Step 2 Unscrew the screws from w...

Page 11: ...rt Pin number of 10 100Base T X RJ45 port is shown in Figure 9 Figure 9 RJ45 Port Pin definition of 10 100Base T X RJ45 port is shown in Table 1 Table 1 Pin Definition of 10 100Base T X RJ45 Port Pin...

Page 12: ...nd RX receive port as seen on the left in Figure 12 100Base FX port wiring is shown on the right in Figure 12 Take SC port as example ST FC wiring method is the same with SC Connect the TX transmit po...

Page 13: ...t requirements use a 5 08mm spacing terminal block to connect power cable Note The cross section area of power cable is required to be greater than 0 75mm2 and less than 2 5mm2 The grounding resistanc...

Page 14: ...ing There is a grounding screw on the top panel of the KOM300M which is for chassis grounding One end of the chassis grounding cable is connected with the grounding screw and the other end of the cabl...

Page 15: ...lectric voltage withstand test in order to avoid test failure please disconnect the 18 AWG yellow green line to disable surge protection circuit which connects to surge grounding Figure 16 Disconnect...

Page 16: ...t Green ON Effective network connection in the port Blinking Network activities in the port OFF No effective network connection in the port 100Base FX port LED LINK ACT On Effective network connection...

Page 17: ...17 Enter Telnet Third click OK and input a default user name admin and password 123 to enter the Telnet configuration interface see Figure 18 Type in a CLI command from Table 4 Figure 18 Telnet Confi...

Page 18: ...ngs Management View SWITCH config terminal Enter configuration view 7 2 Web interface First connect the Ethernet port on the PC to any RJ45 port on the device Second input the IP address of the curren...

Page 19: ...J45 dustproof shield 9 Basic Features and Specifications z Power Requirements Power input 12VDC 9 18VDC 24VAC DC 18 72VDC 18 50VAC Power terminal 5 pin 5 08mm spacing plug in terminal block Power cons...

Page 20: ...KOM300M User s Manual 201110 20 For more information about KYLAND products please visit our website http www kyland cn...