Work Shop use only-Controller work sheet
78
CONTROLLER PARAMETERS
DESIRED SETTINGS
RANGE
UNITS
DESCRIPTION
FAST
SLOW
FORWARD ACCELERATION
15
15
0.1 TO 10S
FAST / SLOW
FORWARD DECELERATION
3
6
0.1 TO 10S
FAST / SLOW
REVERSE ACCELERATION
25
25
0.1 TO 10S
FAST / SLOW
REVERSE DECELERATION
8
10
0.1 TO 10S
FAST / SLOW
FORWARD SPEED(MAX.)
100
45
0 TO 100%
FAST / SLOW
FORWARD SPEED(MIN.)
50
25
0 TO 100%
FAST / SLOW
REVERSE SPEED(MAX.)
35
25
0 TO 100%
FAST / SLOW
REVERSE SPEED(MIN.)
21
21
0 TO 100%
FAST / SLOW
THROTTLE INVERT
NO
NO/YES
See page 35
SLEEP TIMER
10
0 TO 20
MINUTES
PARAMETER NO.
:
36010-LDB4-E500-UK
ECU
:
36000-LDB4-E500-UK
EQ35CB(UK)
P&G SDRIVE 24 Volt 90Amp
CONTROLLER WORKSHEET
NOTE:
*Specifications are subject to change without notice.