2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-4-104
(2-7) U017XX error code table: V.34 transmission
U01700: A communication error that occurs at the transmitting unit in the period after transmission of INFO0
before entering phase 3 (primary channel equivalent device training). For example, INFO0/A/Abar (B/Bbar, for
polling transmission)/INFOh was not detected.
U01720: A communication error that occurs at the transmitting unit in the period after initiating the control
channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected.
U01721: In the absence of a common communication speed between units (including when an impossible
combination of communication speed and symbol speed occurs) after MPh exchange; 1) a DCN signal was
received from the destination unit, and the line was cut; or 2) a DIS (NSF, CSI) signal was received from the
destination unit and, in response to the signal, the unit transmitted a DCN signal, and the line was cut.
U01152
A DCN signal was received after transmission of a CTR signal (ECM).
U01153
A DCN signal was received after transmission of an ERR signal (ECM).
U01154
A DCN signal was received after transmission of an RNR signal (ECM).
U01155
A DCN signal was received after transmission of an SPA signal (short protocol).
U01160
During message reception, transmission time exceeded the maximum transmission time
per line.
U01161
Number of error lines exceeded limits during message reception.
U01162
A break in loop current was detected during message reception.
U01163
Polarity reversal was detected during message reception.
U01164
One page length exceeded the specified length during message reception.
U01170
A decoding error occurred during MMR message reception.
U01172
During reverse polling in V.34 mode at the transmitting unit, a JM signal was not
detected after transmission of a CM signal when receiving after transmission.
U01191
Communication was interrupted because an error occurred during an image data recep-
tion sequence in the V.34 mode.
U01199
A DIS signal with different FIF was received after transmission of a DIS signal.
Error code
Description
U01700
A communication error occurred in phase 2 (line probing).
U01720
A communication error occurred in phase 4 (modem parameter exchange).
U01721
Operation was interrupted due to the absence of a common communication speed
between units.
Error code
Description
Summary of Contents for DP-480
Page 6: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 18: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 This page is intentionally left blank ...
Page 54: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 1 2 24 This page is intentionally left blank ...
Page 172: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 1 3 118 This page is intentionally left blank ...
Page 278: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 2 1 4 106 This page is intentionally left blank ...
Page 434: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 2 2 44 This page is intentionally left blank ...
Page 446: ...2NC 2NF 2NG 2NN 3P7 3P8 3P9 2 3 12 This page is intentionally left blank ...
Page 455: ...Installation Guide DP 480 Document processor Installation Guide ...
Page 458: ...2 3 4 5 6 A ...
Page 459: ...3 7 8 9 B C C ...
Page 460: ...4 10 ...
Page 473: ...PF 480 300 sheet Paper feeder Installation Guide ...
Page 476: ...2 5 6 4 3 B M3x8 B M3x8 B M3x8 B M3x8 1 2 ...
Page 477: ...3 9 10 8 7 1 2 ...
Page 478: ...4 13 12 11 1 2 C ...
Page 479: ...5 15 14 E D D E D D E D D E D D ...
Page 482: ...DU 480 duplex unit Installation Guide ...
Page 484: ...1 2 3 1 A B M3x8 ...
Page 485: ...2 6 7 5 4 A A B M3x8 ...
Page 489: ...IB 33 Network interface kit Installation Guide ...
Page 490: ...2 3 1 IB 33 2013 7 303PB56710 01 A B ...
Page 491: ...6 7 5 4 2013 7 303PB56710 01 B YC2007 A ...
Page 492: ...FAX System X Installation Guide ...
Page 495: ...2 5 4 3 2 B M3x8 A YC 2003 ...
Page 496: ...3 8 9 7 6 C G G 8 9 7 6 C ...
Page 497: ...4 11 10 12 13 D D E ...
Page 499: ......
Page 500: ......