2MF/2MG
1-4-8
1010
Lift motor error
During driving the lift motor,
a motor overcurrent signal
is detected for 5 s.
This error is detected five
times successively.
Defective bottom
plate elevation
mechanism in the
cassette.
Check to see if the bottom plate can move
smoothly and repair it if any problem is found.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
Lift motor and connect-R PWB (YC8)
Connect-R PWB (YC2) and engine PWB
(YC502)
Defective drive
transmission sys-
tem of the lift
motor.
Check if the gears rotate smoothly. If not,
grease the bushes and gears. Check for bro-
ken gears and replace if any.
Defective lift motor. Replace the lift motor
Defective engine
PWB or connect-R
PWB.
Replace the engine PWB or connect-R PWB
and check for correct operation (see page 1-5-
30).
2000
Main motor steady-state
error
The main motor ready input
is not given for 2 s during
the main motor is ON.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
Main motor and engine PWB (YC501)
Defective drive
transmission sys-
tem of the main
motor.
Check if the rollers and gears rotate smoothly.
If not, grease the bushes and gears. Check for
broken gears and replace if any.
Defective main
motor.
Replace the main motor.
Defective engine
PWB.
Replace the engine PWB and check for correct
operation (see page 1-5-30).
2200
Drum motor steady-state
error
The drum motor ready input
is not given for 2 s during
the drum motor is ON.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
Drum motor and engine PWB (YC11)
Defective drive
transmission sys-
tem of the drum
motor.
Check if the rollers and gears rotate smoothly.
If not, grease the bushes and gears. Check for
broken gears and replace if any.
Defective drum
motor.
Replace the drum motor.
Defective engine
PWB.
Replace the engine PWB and check for correct
operation (see page 1-5-30).
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...