2MF/2MG
1-4-10
3500
Communication error
between scanner and
ASIC
An error code is detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
CCD PWB (YC2) and main PWB (YC8)
Defective CCD
PWB.
Replace the scanner unit (see page 1-5-19).
Defective main
PWB.
Replace the main PWB and check for correct
operation (see page 1-5-34).
4000
Polygon motor synchro-
nization error
The polygon motor ready
input is not given for 10 s
during the polygon motor is
ON.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
Laser scanner unit and main PWB (YC14)
Defective polygon
motor.
Replace the laser scanner unit (see page 1-5-
16).
Defective main
PWB.
Replace the main PWB and check for correct
operation (see page 1-5-34).
4200
BD steady-state error
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, remedy
or replace the cable.
Laser scanner unit and main PWB (YC16)
Defective laser
scanner unit.
Replace the laser scanner unit (see page 1-5-
16).
Defective main
PWB.
Replace the main PWB and check for correct
operation (see page 1-5-34).
4700
VIDEO ASIC device error
Mismatch of reading data
from two locations occurs
eight times successively.
Mismatch between writing
data and reading data
occurs eight times succes-
sively.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for continu-
ity within the connector cable. If none, replace
the cable.
Main PWB (YC13) and engine PWB (YC12)
Defective main
PWB or engine
PWB.
Replace the main PWB or the engine PWB and
check for correct operation
(see page 1-5-34, 1-5-30).
5100
Main charger high-volt-
age error
Five pages have been
printed with the main char-
ger output short-circuited.
Drum unit installed
incorrectly.
Verify harness is not pinched.
Engine PWB
installed incor-
rectly.
Verify harness is not pinched.
Defective engine
PWB.
Replace the engine PWB and check for correct
operation (see page 1-5-30).
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...