2MF/2MG-2
1-4-14
F010
Main PWB checksum
error
Defective main
PWB.
Turn the main power switch off/on to restart the
machine. If the error is not resolved, replace
main PWB (see page 1-5-34).
F020
Main PWB RAM check-
sum error
Defective main
memory (RAM) on
the main PWB.
Turn the main power switch off/on to restart the
machine. If the error is not resolved, replace
main PWB.
Defective
expanded memory
(DIMM).
Replace the expanded memory (DIMM).
F040
Main PWB - engine PWB
communication error
Defective main
PWB.
Turn the main power switch off/on to restart the
machine. If the error is not resolved, replace
main PWB.
Defective engine
PWB.
Replace the engine PWB.
F041
Main PWB - scanner
communication error
Defective main
PWB.
Turn the main power switch off/on to restart the
machine. If the error is not resolved, replace
main PWB.
F050
Engine ROM checksum
error
Defective engine
PWB.
Replace the engine PWB and check for correct
operation (see page 1-5-30).
F051
Scan engine ROM check-
sum error
Defective engine
PWB.
Replace the engine PWB and check for correct
operation (see page 1-5-30).
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...