2MF/2MG
1-4-23
(10)
Paper feed clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Paper feed clutch and connect-R PWB (YC5)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the paper feed clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(11)
Registration clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Registration clutch and connect-R PWB (YC6)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the registration clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(12)
Middle clutch does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Middle clutch and connect-R PWB (YC7)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the middle clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(13)
Duplex clutch does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Duplex clutch and connect-R PWB (YC9)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective clutch.
Replace the duplex clutch.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(14)
MP solenoid does
not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
MP solenoid and connect-R PWB (YC10)
Connect-R PWB (YC1) and engine PWB (YC9)
2. Defective solenoid.
Replace the MP solenoid.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
(15)
Developing sole-
noid does not oper-
ate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Developing solenoid and connect-R PWB (YC4)
Connect-R PWB (YC2) and engine PWB (YC502)
2. Defective solenoid.
Replace the developing solenoid.
3. Defective PWB.
Replace the engine PWB or connect-R PWB and check for
correct operation (see page 1-5-30).
Problem
Causes
Check procedures/corrective measures
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...