2MF/2MG
1-5-18
13. Remove two connectors from the main
PWB.
Figure 1-5-26
14. Remove four screws and then remove
the laser scanner unit.
15. Check or replace the laser scanner unit
and refit all the removed parts.
Figure 1-5-27
YC16
YC14
Main PWB
Main PWB
Connectors
Screw
Laser scanner unit
Screw
Screw
Screw