2MF/2MG
1-5-28
6. Release four hooks and then remove
the separation brush unit.
7. Check or replace the transfer roller and
separation brush unit and refit all the
removed parts.
CAUTION:
Note the following, when
refitting the transfer roller and separa-
tion brush unit.
A: Transfer roller
To avoid damaging the bush, place the
transfer roller so that its gear does not
hit the U-shaped bush.
B: Separation brush unit
While inserting the separation holder in
place, align the ends of the holder with
the guides until they click in.
(a)The separation brush unit is inserted
into the two projections of the frame
and does not run on to the projections.
(b)The separation brush unit is firmly in
contact with the separation plate of the
frame.
NOTE:
When the periodic maintenance
(replacing the maintenance kit, see
page 2-4-4), perform maintenance
mode.:
U251 Clearing the maintenance count
(see page 1-3-26)
Figure 1-5-45
B-(a)
B
A
B-(b)
Transfer roller
U-shaped
bush
Shaft
Transfer roller
U-shaped bush
Separation brush unit
Guides
Guides
Gear
View point
Frame
Separetion plate
Separation brush unit
Hook
Projection
Projection
Projection
View point
Separation brush unit
Separation brush
Separation brush unit
Separetion plate
View point
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...