2MF/2MG
1-5-34
(2) Detaching and refitting the main PWB
Procedure
1. Remove the right cover.
(See page 1-5-3)
2. Remove thirteen connectors from the
connect-R PWB.
3. Remove the one screw and then
remove the connect-R PWB.
4. Release two clamps and then remove
the wires.
Figure 1-5-54
YC9
YC8
YC4
YC13
YC6
YC10
YC7
YC3
YC5
YC11
YC12
YC2
YC1
Clamp
Main PWB
Screw
Connect-R PWB
Wire
Wire
Clamp
Connect-R PWB
Connectors
Connectors
Connectors