2MF/2MG
1-5-36
9. Remove the following connectors from
the main PWB.
Twelve connectors: 4in1 model (with
FAX)
Eleven connectors: 3in1 model (with-
out FAX)
10. Remove four screws and then remove
the main PWB.
11. Check or replace the main PWB and
refit all the removed parts.
Figure 1-5-56
YC12
YC3
YC7
YC8
YC1005 YC1008 YC1004
YC14
YC16
YC13
YC15
YC1001
Screw
Main PWB
Main PWB
(4in1 models (with FAX) only)
Connectors
Connectors
Connectors
Connector
Screw
Screw
Screw