9. Remove one connector (YC11) from the
connect-L PWB.
10. Remove the wire from the drum ground-
ing plate and clamp.
11. Release two hooks and then remove
the power source fan motor.
Figure 1-5-59
Connector(YC11)
Connect-L PWB
Drum grounding
plate
Clamp
Wire
Power source fan motor
Hook
Hook