2MF/2MG-3
1-6-1
1-6 Requirements on PWB Replacement
1-6-1 Upgrading the firmware
Follow the procedure below to upgrade the firmware of main PWB (main controller and scanner) and engine
PWB and FAC control PWB and Option language.
Preparation
Extract the file that has the download firmware and put them in the USB Memory.
Procedure
1. Turn ON the main power switch and
confirm if the screen shows “Ready to
print” then, turn OFF the main power
switch.
2. Insert USB memory that has the firm-
ware in the USB memory slot.
3. Turn ON the main power switch.
4. About 40 seconds later, “FW-Update”
will be displayed and blinking the
Memory indicator (this shows to start
the download).
5. Display the software that now upgrad-
ing.
“FW-Update [CTRL]”
“FW-Update [ENGIN]”
“FW-Update [SCAN]”
“FW-Update [FAX ]”
“FW-Update [OPT ]”
Caution:
Never turn off the power switch or remove
the USB flash device during upgrading.
Figure 1-6-1
6. Display the completion of the upgrade
(Memory indicator is ON condition).
7. ROM version is confirmed by the con-
tent of the display.
8. Turn OFF the main power switch and
remove the USB memory.
USB memory
USB memory slot
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...