2MF/2MG
2-3-2
Connector
Pin
Signal
I/O
Voltage
Description
YC101
1
LIVE
I
120 V AC
220-240 V AC
AC power input
Connected to
AC inlet and
main power
switch
2
NEUTRAL
I
120 V AC
220-240 V AC
AC power input
YC102
1
COMMON1
O
120 V AC/0V
220-240 V AC/0V
FH: On/Off
Connected to
relay PWB
2
N.C
-
-
Not used
3
LIVE
O
120 V AC220-240
V AC
AC power to RYPWB
YC103
1
+5V1
O
5 V DC
5 V DC power to CPWB-L
Connected to
connect-L
PWB
2
+5V1
O
5 V DC
5 V DC power to CPWB-L
3
+5V1
O
5 V DC
5 V DC power to CPWB-L
4
+24V1
O
24 V DC
24 V DC power to CPWB-L
5
HUNITN
O
0/5 V DC
EVFSW: On/Off
6
HANDSN
O
0/5 V DC
MPPS: On/Off
7
N.C.
-
-
Not used
8
HEATONN1
I
0/5 V DC
FH: On/Off
9
ZCROSS
O
0/5 V DC (pulse)
Zero-cross signal
10
SWSLEEPN
I
0/5 V DC
Sleep mode signal: On/Off
11
+24V2
O
24 V DC
24 V DC power to CPWB-L (via ILSW)
12
GND
-
-
Ground
13
GND
-
-
Ground
14
GND
-
-
Ground
15
GND
-
-
Ground
16
+24V2
O
24 V DC
24 V DC power to CPWB-L (via ILSW)
17
+24V2
O
24 V DC
24 V DC power to CPWB-L (via ILSW)
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...