2MF/2MG
2-3-4
Connector
Pin
Signal
I/O
Voltage
Description
YC5
1
OPSDO
O
0/5 V DC (pulse)
Serial communication data signal output
Connected to
connect-L
PWB
2
+24V2
I
24 V DC
24 V DC power from CPWB-L (via ILSW)
3
+24V2
I
24 V DC
24 V DC power from CPWB-L (via ILSW)
4
GND
-
-
Ground
5
GND
-
-
Ground
6
GND
-
-
Ground
7
GND
-
-
Ground
8
GND
-
-
Ground
9
+24V1
I
24 V DC
24 V DC power from CPWB-L
10
+5V1
I
5 V DC
5 V DC power from CPWB-L
11
+5V1
I
5 V DC
5 V DC power from CPWB-L
12
+5V1
I
5 V DC
5 V DC power from CPWB-L
13
+5V2
O
5 V DC
5 V DC power to CPWB-L
YC7
1
GND
-
-
Ground
Connected to
lift sensor
2
LIFTSEN
I
0/5 V DC
LS: On/Off
3
+5V2
O
5 V DC
5 V DC power to LS
YC9
1
WETCLK2
O
0/5 V DC (pulse)
TEMS clock signal
Connected to
connect-R
PWB
I
Analog
TEMS detection voltage (humidity)
2
WETCLK1
O
0/5 V DC (pulse)
TEMS clock signal
3
+5V1
O
5 V DC
5 V DC power to CPWB-R
4
AIRTEMP
I
Analog
TEMS detection voltage (temperature)
5
RFANDRN
O
0/12/24 V DC
RFM: Full speed/Half speed/Off
6
+24V1
O
24 V DC
24 V DC power to CPWB-R
7
MPFDRN
O
0/24 V DC
MPSOL: On/Off
8
OUTB2
O
0/24 V DC (pulse)
SBM drive control signal
9
OUTB1
O
0/24 V DC (pulse)
SBM drive control signal
10
OUTA2
O
0/24 V DC (pulse)
SBM drive control signal
11
OUTA1
O
0/24 V DC (pulse)
SBM drive control signal
12
GND
-
-
Ground
YC11
1
+24V4
O
24 V DC
24 V DC power to DRM
Connected to
drum motor
2
GND
-
-
Ground
3
DMOTRDYN
I
0/5 V DC
DRM ready signal
4
DMOTCLK
O
0/5 V DC (pulse)
DRM clock signal
5
DMOTONN
O
0/5 V DC
DRM: On/Off
Summary of Contents for ECOSYS FS-3040MFP+
Page 1: ...SERVICE MANUAL Published in May 2013 842MG116 2MGSM066 Rev 6 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 218: ...2MF 2MG 2 1 24 This page is intentionally left blank ...
Page 226: ...2MF 2MG 2 2 8 This page is intentionally left blank ...
Page 250: ...2MF 2MG 2 3 24 This page is intentionally left blank ...
Page 270: ...2MF 2MG 2 4 20 This page is intentionally left blank ...