2MF/2MG
2-3-7
YC506
1
FUSER-L
I
2 to 5 V DC
EVSW-L detection voltage
Connected to
fuser unit
2
FUSER-R
I
2 to 5 V DC
EVSW-R detection voltage
3
+5V1
O
5 V DC
5 V DC power to fuser unit
4
THERM3
-
-
Not used
5
+5V2
O
5 V DC
5 V DC power to ES
6
EXITPAP
I
0/5 V DC
ES: On/Off
7
GND
-
-
Ground
8
THERM1
I
Analog
FTH1 detection voltage
9
+5V1
O
5 V DC
5 V DC power to FTH1
10
FDDRN
O
0/24 V DC
FSSOL: On/Off
11
+24V2
O
24 V DC
24 V DC power to FSSOL
12
FUDRN
O
0/24 V DC
FSSOL: On/Off
13
+5V2
O
5 V DC
5 V DC power to DUS
14
DUPAP
I
0/5 V DC
DUS: On/Off
15
GND
-
-
Ground
16
+5V1
O
5 V DC
5 V DC power to FTH2
17
THERM2
I
Analog
FTH2 detection voltage
Connector
Pin
Signal
I/O
Voltage
Description