2MF/2MG
2-3-20
YC7
1
+24V2
O
24 V DC
24 V DC power to MCL
Connected to
middle clutch
2
MIDDRN
O
0/24 V DC
MCL: On/Off
YC8
1
LMOTON
O
0/24 V DC
LM: On/Off
Connected to
lift motor
2
GND
-
-
Ground
YC9
1
+24V2
O
24 V DC
24 V DC power to DUCL
Connected to
duplex clutch
2
DUDRN
O
0/24 V DC
DUCL: On/Off
YC10
1
+24V2
O
24 V DC
24 V DC power to MPSOL
Connected to
MP solenoid
2
MPFDRN
O
0/24 V DC
MPSOL: On/Off
YC11
1
+24V1
O
24 V DC
24 V DC power to RFM
Connected to
right fan
motor
2
RFANDRN
O
0/12/24 V DC
RFM: Full speed/Half speed/Off
YC12
1
ATRTEMP
O
5 V DC
5 V DC power to FUSW
Connected to
fuser unit
switch
2
ATRTEMP2
I
0/5 V DC
FUSW: On/Off
YC13
1
+24V1
O
24 V DC
24 V DC power to EFM
Connected to
eject fan
motor
2
EXITFAN
O
0/24 V DC
EFM: On/Off
Connector
Pin
Signal
I/O
Voltage
Description